Chat with us, powered by LiveChat

Radar

Which measuring instrument fits your application?

Select your measurement device

Technical data

  • Process pressure: –1 to +3 bar/-14.5 to 43.5psi
  • Process temperature: –40 to +130 °C/-40 to 266 °F
  • Accuracy: ±2 mm/±0.08″
  • Process connection: G 1½”, 1½” NPT, DN 80 to DN 150/3″ to 6″
  • Wetted parts: PTFE, PVDF, Viton, PP, sealings
  • Measuring ranges: 30 m/98ft

Application limits

  • Ammoniacal gas phase: FMR54 in stilling well
  • Strong build-up formation: FMR54 with air purge
  • Low DC: FMR51
  • Only PTFE resistant: FMR52
  • Custody transfer measurement: FMR540

Technical data

  • Process pressure: –1 to +160 bar/-14.5 to +2320psi
  • Process temperature: –196 to +450°C/-321 to +842 °F
  • Accuracy: ±2 mm/±0.08″
  • Process connection: R 1½”, DN 50 to DN 150, Tri-Clamp
  • Wetted parts: 316L/1.4435, Alloy C, PTFE, sealings
  • Measuring ranges: 40 m/131ft
  • Gastight feed through: Optional

Application limits

Technical data

  • Process pressure:–1 to +25 bar/-14.5 to 6+362.5psi
  • Process temperature: –40 to +200 °C/-40 to 392 °F
  • Accuracy: ±2 mm/±0.08″
  • Process connection: DN 50 to DN 150, Tri-Clamp, hygienic connections
  • Wetted parts: PTFE
  • Measuring ranges: 40 m/131ft
  • Gastight feed through: Optional

Application limits

Technical data

  • Process pressure: –1 to +40 bar/-14.5 to +580psi
  • Process temperature: –40 to +150 °C/-40 to 302 °F
  • Accuracy: ±6 mm/0.24″
  • Process connection: R 1½”, DN 50 to DN 150/2″ to 6″
  • Wetted parts: 316L/1.4435, PTFE, PVDF, sealings
  • Accuracy: 20 m/65ft
  • Gastight feed through: Optional

Application limits

Technical data

  • Process pressure: –1 to +160 bar/-14.5 to +2320psi
  • Process temperature: –196 bis +400 °C/-321 to +752 °F
  • Accuracy: ±6 mm/±0.24″
  • Process connection: DN 80 to DN 250/3″ to 10″
  • Wetted parts: 316L/1.4435, Alloy C, PTFE, ceramics, graphite, sealings
  • Measuring ranges: 20 m/65ft
  • Gastight feed through: Standard

Application limits

Technical data

  • Process pressure: –1 to +16 bar/-14.5 to 232psi
  • Process temperature: –40 to +130 °C/-40 to +266 °F
  • Accuracy: ±1 mm/±0.04″
  • Process connection: thread G1-1/2″, MNPT1-1/2″; flange DN 80 to DN 150/3″ to 6″
  • Wetted parts: PTFE Antenna, PP or 316L process connection
  • measuring ranges: 50 m/164ft
  • Gastight feed through: Optional

Application limitations

Technical data

  • Process pressure: –1 to +25 bar/-14.5 to +362.5psi
  • Process temperature: –40 to +200 °C/-40 to +302 °F
  • Accuracy: ±1 mm/±0.04″
  • Process connection: thread G, MNPT 3/4″, 1-1/2″; flange DN 80 to DN 150/3″ or 6″, ASME 2″ to 6″; DIN11851, Tri-Clamp
  • Wetted materials: PTFE or PEEK Antenna,  316L thread or PTFE plated flange
  • Measuring ranges: 80 m/262ft
  • Gastight feed through: Optional

Application limits